Questions
Tags
Users
Badges
All Questions
Newest
Active
Unanswered
Frequent
More
Score
View
Card
Compact
Orne Brocaar
1246
•
asked 18h ago
ChirpStack v4.19.2
v4.19.2 Bugfixes Apply the validated tenant_id to the MulticastGroupService::list query ( [cec1896] ).
announcements
0
votes
0
answers
5
views
Patrik Edberg
1
•
asked Sep 17
Problem with InfluxDB (v1.6) when upgrading from 4.16.2 to 4.17
I have not upgraded regurlely lately and today i upgraded from 4.16.1-1 to 4.19 and a strange thing happened. The data written to influx integrations stopped. When i downgraded to 4.16.1-1 again it started working again. I upgradede til 4.1...
integrations
chirpstack
influxdb
0
votes
0
answers
8
views
Nik Teterski
3
•
asked Sep 14
Chirpstack UDP Forwarder Gets Empty Gateway ID Resulting in Error
Hello, I have a Concentratord + Chirpstack UDP Forwarder setup I am trying to get working, but am running into an issue. I have no issue sending messages from Concentratord to the Chirpstack Gateway Bridge, but when I try sending to the Chi...
troubleshooting
chirpstack-concentratord
chirpstack-udp-forwarder
0
votes
2
answers
16
views
Vishnu Kumar
5
•
asked Sep 12
Looking for ChirpStack specialists (Not sure if I should be posting this here)
Hey there, First off, many apologies if what I'm about to say isn't appropriate for this forum. This forum seems new and so I'm not sure what the exact rules are here. We operate a energy management startup and are involved with...
chirpstack
0
votes
1
answers
27
views
zouxc
1
•
asked Sep 8
FUOTA - verification error / incorrect session keys
When I was using LORAWAN 1.0.3, the firmware deployment for fuota was completed. However, I found that the downloaded fragmented firmware was not received successfully. The reason was a verification error during the multicast group distribu...
devices
chirpstack
fuota
0
votes
0
answers
24
views
Friedrich Kronemeyer
1
•
asked Sep 7
Class-c downlink removed from queue but Never transmitted
Hello, I am using a local ChirpStack instance on a Seeed SenseCAP M2 gateway (EU868). My Aqua-Scope KFRLWE02 joins successfully via OTAA and sends uplinks correctly on FPort 10. The device profile has Class C enabled. The manufacturer confi...
lorawan
0
votes
2
answers
41
views
Vishnu Kumar
5
•
asked Sep 4
Chirpstack Mesh - Relay Gateway clock not synced, does it matter?
Hey everyone, We recently deployed a Mesh system involving 1 border gateway and 2 relay gateways. The relays aren't connected to internet. When we first installed the relay, we synced relay time to browser time. Now on the Chirpstack Se...
gateways
chirpstack-gateway-mesh
0
votes
1
answers
40
views
1
•
asked Aug 30
Announcing chirpstack-mcp-server — manage and live-debug LoRaWAN devices from an AI coding agent (gRPC)
Hi all, I have been building an application on top of ChirpStack and wanted my coding agent (Claude Code, but any MCP client works) to be able to enqueue a downlink, watch the uplink come back, tweak the payload codec and check link quality...
integrations
0
votes
0
answers
37
views
Arthur
3
•
asked Aug 29
ABP device never seen by application although gateway receives frames
Hello, I am using the LilyGo T3 V1.6.1 LoRa module with lmic library. When I use the OTAA procedure, everything works fine. For battery‑powered operation I tried switching to ABP. Unfortunately, no messages are arriving in the application. ...
troubleshooting
devices
chirpstack
abp
0
votes
2
answers
83
views
Stefan Mutschlechner
1
•
asked Aug 28
Join Accept
I have 19 Gateways in Merano. 5 Gateways on Mountain Roads Arrondissement the City on high Positions. 14 dow in the Cities on Light poles. The problem is that sometimes Chirpstack choose for Join request Gateways with really low RSSI and SN...
chirpstack
0
votes
1
answers
46
views
1
(current)
2
3
4
5
Next
Next
Hot Questions
ChirpStack v4.19.2
Problem with InfluxDB (v1.6) when upgrading from 4.16.2 to 4.17
Chirpstack UDP Forwarder Gets Empty Gateway ID Resulting in Error
2 answers
Looking for ChirpStack specialists (Not sure if I should be posting this here)
1 answers
Class-c downlink removed from queue but Never transmitted
2 answers
FUOTA - verification error / incorrect session keys