Questions
Tags
Users
Badges
All Questions
Newest
Active
Unanswered
Frequent
More
Score
View
Card
Compact
Julie
1
•
asked 14h ago
Gateways Mesh not showing in Chirpstack
Hi, We are currently running a test platform using ChirpStack 4.12.1 with Mesh Gateways running ChirpStack Gateway OS 4.10.1. Communication between all components is working correctly, and the gateways are operational. However, the Mesh Gat...
chirpstack
0
votes
0
answers
4
views
Orne Brocaar
916
•
asked Apr 14
ChirpStack Concentratord v4.7.1
v4.7.1 Features Add support for Elecro LR1302 shield. ( [#280] )
announcements
0
votes
0
answers
9
views
Silvia Montoya
1
•
asked Apr 13
Mismatch between “Expected Uplink Interval” and Dashboard active device count
Hi there, I’m seeing a discrepancy between the Expected Uplink Interval defined in the Device Profile and the number of “active devices” shown in the Dashboard. For example: In the Device Profile I set Expected uplink interval = 3600 second...
api
chirpstack
0
votes
1
answers
9
views
Rob
1
•
asked Apr 12
disable_mac_commands=true
Is there somewhere an option to disable mac commands as we had this in older chirpstack versions. Currently I am running the newest RPI firmware version. On older versions this was configured in the chirpstack.toml file but that isn't p...
configuration
chirpstack
0
votes
2
answers
13
views
Mitch
1
•
asked Apr 10
Basic Station Certs Generator
Howdy everybody, new here but have been enjoying ChirpStack very much for several months now. I want to talk about Basic Station gateways for a second. I understant there is no CUPS support from CS which is fine and well, but has there been...
gateways
chirpstack
basics-station
chirpstack-gateway-bridge
0
votes
1
answers
13
views
Marco Ratto
1
•
asked Apr 8
Clarification on Duty-Cycle enforcement logic in ChirpStack (EU868)
Hi, Regarding EU868 regional duty-cycle regulations (ETSI EN300.220-2), which typically cap transmissions at 1% (36s/hour): I would like to clarify how ChirpStack handles this internally: Downlink Scheduling Does ChirpStack enforce a mandat...
chirpstack-concentratord
chirpstack
0
votes
2
answers
30
views
AreaProject
5
•
asked Apr 8
Backup and Restore Network session key
Good morning, We've recently been experiencing a reading issue with many heat metering devices. They haven't been received since day X without any errors or gateway issues. (We've already ruled out a gateway-related issue becaus...
bug
troubleshooting
0
votes
2
answers
40
views
Cory
18
•
asked Apr 7
v4.17 JS Decode Error after update from v4.16
I have a few devices which are not decoding correctly now since my console has been updated to v4.17 last week. One i have noticed is the merry iot open/close sensor, chirpstack with quickjs now throws a Code: UPLINK_CODEC Level: ERROR for ...
chirpstack
codecs
0
votes
2
answers
36
views
Tiago
1
•
asked Apr 6
Join-request received by gateway and seen in ChirpStack troug/ no join-accept (AU915)
Hello ChirpStack support team, I'm contacting you because I'm experiencing an issue with an AU915 configuration where the gateway is receiving OTAA join requests, but no frames are being seen on the ChirpStack server. Current config...
troubleshooting
devices
gateways
chirpstack
0
votes
1
answers
20
views
Igor Pereverzev
9
•
asked Mar 31
"ENFORCE_DC" model flag on regions different from EU868
Hello! Does model flag "ENFORCE_DC" make any sense on region RU864?
chirpstack-concentratord
0
votes
1
answers
23
views
1
(current)
2
3
4
5
Next
Next
Hot Questions
Gateways Mesh not showing in Chirpstack
ChirpStack Concentratord v4.7.1
Mismatch between “Expected Uplink Interval” and Dashboard active device count
1 answers
disable_mac_commands=true
2 answers
Clarification on Duty-Cycle enforcement logic in ChirpStack (EU868)
2 answers
Basic Station Certs Generator
1 answers